FP - With flow cartridge from the p-line
EP - Offline-filter with motor-pump

AMCA Constant Flow Filters perform better

In real conditions some filter elements tend to perform not as well as evaluated through a multipass test. Variable flow rate and vibration show an unacceptable drop in removal efficiency (ß-rating) and dirtcapacity. Clouds of contamination, downstream the filter, could result in component failure.

AMCA Constant Flow Filters (ACFF)ensure that hydraulic fluid continually circulates through the filter elements at a constant flow rate. Thus meeting the steady state conditions of the multipass test and keeping the system clean at all time.

The AMCA-ACFF-3 element offers the following benefits:

  • Due to the removal of the metal parts of the elements, the disposal weight will be reduced by more than 50%.
  • The remaining oil in the element can be removed by means of simple pressing sequence. This will reduce the disposal costs even more.
  • The metal re-useable sleeve is made from durable materials.
  • The elements are equipped with a silicone bottom in order to prevent dirt being flushed back during element change.
  • The elements are equipped with the glass fibre media with filtration finenesses of 1 or 3 micron
Technical Data
E-Motor supply EP:240VAC, 240/400VAC
Nominal working pressure (inlet) 350 bar (5000 psi)
Nominal flow rate 2, 4, 6 and 8 l/min (0.5, 1.0, 1.6 and 2.1 USgpm)
Filtration rating ß3 > 200
Filter element max. work pressure 2.5 bar (35.7 psi)
Filter housing max. work pressure 5 bar (71.5 psi)
Mounting position Vertical
Size working port (inlet) FP: 1/4"BSP
EP: 3/8"BSP
Size working port (outlet) 3/8" BSP
By-pass setting 2.0 bar (28.6 psi)
Max. fluid temperature + 80°C (+ 176°F)
Viscosity range 10…500cSt
Indicator Pressure gauge 2.5 bar (35.7 psi)
Media AMCA-ACFF-3

top of the page

< back to contamination control

< back to homepage