< back to contamination control
AIR SENTRY® 1512L143|
|
AIR SENTRY® inclosed breather Replaces the standard filtercap or vent tube on Tank and Reservoir and will give you CLEAN DRY AIR.
|
| The inclosed breather is developed for working under wet conditions
and areas with extreme high humidity levels. |
|
| AIR IN | |
| When the reservoir inhales, air is drawn in through the 4
channels of 6mm, 90° apart of the Topsection (1). The air will pass
a checkvalve (4), which opens, at a vacuum of 0.02 bar. AIR will enter the
standard L134 filter and passes a plastic screen (5) that works like an
Air diffuser to bring it trough the 2 micron filter (6) to remove particulate
contamination's. Moisture will be removed by the high capacity desiccant (7). The Air will pas the Bottom section where an Air filter optional vacuum indicator can be mounted (8). Filter has a ½" female connection on the bottom (9) |
|
| AIR OUT | |
| When the reservoir exhales, Air passes the check valves in the Bottom section at 0.02 bar pressure. This filterunit can be used on 99% of all applications. | |