< back to homepage

<back to proportional valves

Products - Control Valves- MEV
PROPORTIONAL DIRECTIONAL CONTROL VALVE
MEV - Electrical operation

Features

  • Load independent flow control corresponds to the spool-position proportional to the electrical input signal.
  • The pump pressure always corresponds to the user pressure, +3,6,8 or 12 bar (43, 86, 114 or 172 psi) Dp compensator.
  • The built-in pump-unloading valve results in:
       - very low power turned into heat;
       - minimum loading of the prime mover.
  • User speed is precisely controlled under all load conditions.
  • Progressive regulating curve; no pressure peaks when switching; sensitive control even for altern-ating pressures.
  • Constant working speed of differential cylinders at the different regulating flow to the valve by grinding angle.
  • Constant recirculation pressure independent of the number of units.
  • Any limiting of flow for every user port.
  • Load independent switching adjustment, constant acceleration and deceleration.
  • Proportional solenoids with longer life for the armature in the oil (explosion proof solenoids "EEx mII T4 or T5", available).
  • Proportional directional control valves also available as:
       - Manual proportional series MHV
       - Hydraulic proportional series MOV. Any combination of these control options is possible.
  • The sub plate system allows a construction up to 8 control valves.
Technical Data
Operating pressure (P,A,B) ...350 bar (5000 psi)
Maximum return pressure (T):
- aluminium springcaps
- cast iron springcaps


15 bar (214 psi)
30 bar (428 psi)

Dp compensator 3; 6; 8 or 12 bar (43; 86; 114 or 172 psi)
Pressure setting range 5...350 bar (72...5000 psi)
Flow range (see table 1) ...800 l/min (...211 USgpm) - with 32 cSt at 40 o C
Fluid Mineral oil according to DIN 51524/51525
Fluid temperature range -35...+80°C (-31°...+176°F)
Viscosity range 2,8...380 cSt, optimal 30 cSt
Contamination level max. according to NAS 1638 Class 9 or ISO 18/15
Nominal voltage 12 V, 24 V
Nominal current 12 V DC = 1.400 mA ; 24 V DC = 700 mA
Hysteresis 3...8% (50...800 l/min (13...211 USgpm))
Continuous operating 100%
Type of protection IP 65, optional IP67/EEx m II T4
Recommended dither frequency 100Hz
Mounting position optional
Size working ports:
(in subplate)

MEV12 : 1/2" BSP (SAE optional)
MEV16 : 3/4" BSP (SAE optional)
MEV20 : 1" BSP (SAE optional)
MEV25 : 1 1/4" BSP (SAE optional)
MEV32 : 1 1/2" BSP (SAE optional)




Table 1
Max. flow in l/min. (USgpm) related to the Dp in bar (psi) over the compensator, per nominal bore
 
Size
Dp compensator
 
3(43) *
6(86)
8(114)
12(172) **
bar (psi)
MEV12
50(13)
80(21)
90(24)
100(26)
l/min (USgpm)
MEV16
100(26)
140(37)
155(41)
180(47)
 
MEV20
160(42)
225(59)
250(66)
300(79)
 
MEV25
250(66)
350(92)
390(103)
500(132)
 
MEV32
400(106)
500(132)
550(145)
800(211)
 
* For the MEV only valid with
external pilot supply
 
** Due to loss of pressure
c.q. energy conversion into
heat, we recommend the
next largest size related
to a lower Dp compensator.


top of the page