Features
|
- Load independent flow control corresponds to the
spool-position proportional to the electrical input
signal.
- The pump pressure always corresponds to the user
pressure, +3,6,8 or 12 bar (43, 86, 114 or 172 psi)
Dp compensator.
- The built-in pump-unloading valve results in:
- very low power turned into heat;
- minimum loading of the prime mover.
- User speed is precisely controlled under all load
conditions.
- Progressive regulating curve; no pressure peaks
when switching; sensitive control even for altern-ating
pressures.
- Constant working speed of differential cylinders at
the different regulating flow to the valve by grinding
angle.
- Constant recirculation pressure independent of the
number of units.
- Any limiting of flow for every user port.
- Load independent switching adjustment, constant
acceleration and deceleration.
- Proportional solenoids with longer life for the
armature in the oil (explosion proof solenoids "EEx
mII T4 or T5", available).
- Proportional directional control valves also
available as:
- Manual proportional series MHV
- Hydraulic proportional series MOV.
Any combination of these control options is
possible.
- The sub plate system allows a construction up to
8 control valves.
|
| Technical Data |
| Operating pressure (P,A,B) |
...350 bar (5000 psi) |
Maximum return pressure (T):
- aluminium springcaps
- cast iron springcaps |
15 bar (214 psi)
30 bar (428 psi)
|
| Dp compensator |
3; 6; 8 or 12 bar (43; 86; 114 or 172 psi) |
| Pressure setting range |
5...350 bar (72...5000 psi) |
| Flow range (see table 1) |
...800 l/min (...211 USgpm) - with 32 cSt at 40 o C |
| Fluid |
Mineral oil according to DIN 51524/51525 |
| Fluid temperature range |
-35...+80°C (-31°...+176°F) |
| Viscosity range |
2,8...380 cSt, optimal 30 cSt |
| Contamination level max. |
according to NAS 1638 Class 9 or ISO 18/15 |
| Nominal voltage |
12 V, 24 V |
| Nominal current |
12 V DC = 1.400 mA ; 24 V DC = 700 mA |
| Hysteresis |
3...8% (50...800 l/min (13...211 USgpm)) |
| Continuous operating |
100% |
| Type of protection |
IP 65, optional IP67/EEx m II T4 |
| Recommended dither frequency |
100Hz |
| Mounting position |
optional |
Size working ports:
(in subplate) |
MEV12 : 1/2" BSP (SAE optional)
MEV16 : 3/4" BSP (SAE optional)
MEV20 : 1" BSP (SAE optional)
MEV25 : 1 1/4" BSP (SAE optional)
MEV32 : 1 1/2" BSP (SAE optional)
|